Monday, May 13, 2013

PRI VOICE configuration with MGCP Protocol




PRI VOICE configuration with MGCP Protocol


PRI interface configuration for a voice circuit with an assumption that the cable is located at slot #0 and port #2



network-clock-participate wic 0

network-clock-select 1 T1 0/2/0     >>>> clock priority

controller T1 0/2/0

 cablelength long 0db

 pri-group timeslots 1-24 service mgcp





interface Serial0/2/0:23

 no ip address

 encapsulation hdlc

 isdn switch-type primary-ni

 isdn incoming-voice voice

 isdn bind-l3 ccm-manager

 no cdp enable



RTR01#sh network

  Network Clock Configuration

  ---------------------------

  Priority      Clock Source    Clock State     Clock Type



     1          T1 0/2/0        GOOD            T1          primary

    10          Backplane       GOOD            PLL          backup



T1 0/2/0 is up.

  Applique type is Channelized T1

  Cablelength is long 0db

  No alarms detected.

  alarm-trigger is not set

  Soaking time: 3, Clearance time: 10

  AIS State:Clear  LOS State:Clear  LOF State:Clear

  Version info FPGA Rev: 08121917, FPGA Type: PRK4

  Framing is ESF, Line Code is B8ZS, Clock Source is Line.



         